SEVD-2025-014-04 — Web Designer for Modicon Communication Modules

HIGH
CVSS 7.8
Date 2026-10-16T20:32:44+00:00
Source schneider-electric
Published by Schneider Electric

// Description

# Schneider Electric Security Notification 14-Jan-25 Document Reference Number – SEVD-2025-014-04 Page 1 of 4 ## Web Designer for Modicon Communication Modules 14 January 2025 Overview Schneider Electric is aware of a vulnerability in its Web Designer configuration tool for the following Modicon communication modules: • BMXNOR0200H • BMXNOE0110(H) • BMENOC0311(C) • BMENOC0321(C) The Web Designer product is a software application used to create Web-based operator panels and configure operating parameters for Web human machine interface (Web HMI) devices. Failure to apply the Mitigations provided below may risk XML external entity attack, which could result in information disclosure, workstation integrity and potential remote code execution on the compromised computer. Affected Products and Versions Product Version Web Designer for BMXNOR0200H Web Designer for BMXNOE0110(H) Web Designer for BMENOC0311(C) Web Designer for BMENOC0321(C) All versions Vulnerability Details CVE ID: CVE-2024-12476 CVSS v3.1 Base Score 7.8 | High | CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVSS v4.0 Base Score 8.4 | High | CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause information disclosure, impacts workstation integrity and potential remote code execution on the compromised computer, when specific crafted XML file is imported in the Web Designer configuration tool. The severity of vulnerabilities was calculated using the CVSS Base metrics for 4.0 (CVSS v4.0). CVSS v3.1 will be still evaluated until the adoption of CVSS v4.0 by the industry. The severity was calculated without incorporating the Temporal and Environmental metrics. Schneider Electric recommends that customers score the CVSS Environmental metrics, which are specific to end-user organizations, and consider factors such as Schneider Electric Security Notification

// Vulnerabilities (1)

CVE ID CVSS Score Severity Description
CVE-2024-12476 7.8 high
The affected product is vulnerable to an improper restriction of XML external entity reference vulnerability that could cause information disclosure, impacts to workstation integrity and potential remote code execution on the compromised computer, when a specifically crafted XML file is imported in the Web Designer configuration tool.

// Remediations (17)

Mitigation: Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. bef
Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.
Mitigation: When remote access is required, use secure methods, such as virtual private networks (VPNs). Recogni
When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.
Mitigation: For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices docume
For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.
Mitigation: Minimize network exposure for all control system devices and systems and ensure that they are not ac
Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.
Mitigation: Compute a hash of the project files and regularly check the consistency of this hash to verify the i
Compute a hash of the project files and regularly check the consistency of this hash to verify the integrity before usage.
Mitigation: Only open project files received from a trusted source.
Only open project files received from a trusted source.
Mitigation: Never allow mobile devices that have connected to any other network besides the intended network to
Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.
Mitigation: Web Designer tool project file is based on XML language with specific parameters. To ensure the inte
Web Designer tool project file is based on XML language with specific parameters. To ensure the integrity of this file please follow the recommendations below:
Mitigation: Never connect programming software to any network other than the network intended for that device.
Never connect programming software to any network other than the network intended for that device.
Mitigation: For more information, see Schneider Electric security notification "SEVD-2025-014-04 Web Server on M
For more information, see Schneider Electric security notification "SEVD-2025-014-04 Web Server on Modicon M340 and BMXNOE0100/0110, BMXNOR0200H communication modules"
Mitigation: When exchanging files over the network, use secure communication protocols.
When exchanging files over the network, use secure communication protocols.
Mitigation: Place all controllers in locked cabinets and never leave them in the "Program" mode.
Place all controllers in locked cabinets and never leave them in the "Program" mode.
Mitigation: Install physical controls so no unauthorized personnel can access your industrial control and safety
Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.
Mitigation: Encrypt project file (XML configuration file) when stored and restrict the access to only trusted us
Encrypt project file (XML configuration file) when stored and restrict the access to only trusted users.
Mitigation: Locate control and safety system networks and remote devices behind firewalls and isolate them from
Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.
Mitigation: Schneider Electric strongly recommends the following industry cybersecurity best practices.
Schneider Electric strongly recommends the following industry cybersecurity best practices.
Mitigation: To ensure you are informed of all updates, including details on affected products and remediation pl
To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric's security notification service here: https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp