PowerLogic ION8650 / ION8800 / ION7x50 / ION7700/73xx / ION83xx/84xx/85xx/8600 Power Meters (V2.0)

HIGH
CVSS 7.5
Date 2026-10-16T20:40:57+00:00
Source schneider-electric
Published by Schneider Electric

// Description

Schneider Electric Security Notification 9-Mar-21 (15-Mar-21) Document Reference Number – SEVD-2021 -068-03 V2.0 Page 1 of 5 ## PowerLogic ION8650 / ION8800 / ION7x50 / ION7700/73xx / ION83xx/84xx/85xx/8600 Power Meters (V2.0) 9 March 2021 (15 March 2021) # Overview Schneider Electric is aware of a vulnerability in its PowerLogic ION8650, ION8800, ION7x50, ION7700/73xx, and ION83xx/84xx/85xx/8600 products. The PowerLogic metering products are revenue and power quality meters for utility and industrial electrical network monitoring. Failure to apply the mitigations/remediations provided below may risk meter reboot, which could result in unintended device behavior. March 2021 update : Affected product reference 'ION7650' changed to 'ION7x50' to encompass all affected product model references in this model series # Affected Products and Versions Product Version ION8650 All versions prior to V4.40.1 ION8800 All versions prior to V372 ION7x50 (Hardware rev. 4 or earlier*) All versions prior to V376 ION7x50 (Hardware rev. 5*) All versions prior to V416 ION7700/73xx All versions ION83xx/84xx/85xx/8600 All versions *For details regarding how to determine hardware version, please refer to: https://www.se.com/ww/en/faqs/FA328667/ # Vulnerability Details CVE ID: CVE-2021-22713 CVSS v3.0 Base Score 7.5 | High | CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H A CWE-119: Improper restriction of operations within the bounds of a memory buffer vulnerability exists that could cause the meter to reboot. Schneider Electric Security Notification 9-Mar-21 (15-Mar-21) Document Reference Number – SEVD-2021 -068-03 V2.0 Page 2 of 5 # Remediation Affected Product & Version Remediation ION8650 All versions prior to V4.40.1 V4.40.1 (released 4 January 2021) of the PowerLogic ION8650 firmware includes a fix for this vulnerability. The version update files are available for download here:

// Vulnerabilities (1)

CVE ID CVSS Score Severity Description
CVE-2021-22713 7.5 high
A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION8650, ION8800, ION7650, ION7700/73xx, and ION83xx/84xx/85xx/8600 (see security notifcation for affected versions), which could cause the meter to reboot.

// References