IM
IronMonkey Threat Research

CVE-2023-5987 MEDIUM

Published: 2023-11-15 | Last Modified: 2024-11-21 | Status: Modified

Description

A CWE-79 Improper Neutralization of Input During Web Page Generation (Cross-site Scripting) vulnerability that could cause a vulnerability leading to a cross site scripting condition where attackers can have a victim’s browser run arbitrary JavaScript when they visit a page containing the injected payload.

Additional Descriptions (1)

Una vulnerabilidad CWE-79: Neutralización Inadecuada de la Entrada Durante la Generación de Páginas Web (Cross-site Scripting) que podría causar una vulnerabilidad que conduzca a una condición de Cross-Site Scripting donde los atacantes pueden hacer que el navegador de la víctima ejecute JavaScript arbitrario cuando visitan una página que contiene un payload inyectado.

CVSS Metrics

Base Score: 6.1 (MEDIUM)

CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N

Attack VectorNETWORK
Attack ComplexityLOW
Privileges RequiredNONE
User InteractionREQUIRED
ScopeCHANGED
Confidentiality ImpactLOW
Integrity ImpactLOW
Availability ImpactNONE

Source: [email protected]

Type: Primary

Exploitability Score: 2.8

Impact Score: 2.7

Weaknesses

Source Type Description
[email protected] Secondary
en CWE-79

Affected Products

Vendor Product Version Update Type
schneider-electric ecostruxure_power_monitoring_expert 2020 <built-in method update of dict object at 0x7e6111a184c0> Application
schneider-electric ecostruxure_power_monitoring_expert 2020 <built-in method update of dict object at 0x7e6111aa2200> Application
schneider-electric ecostruxure_power_monitoring_expert 2020 <built-in method update of dict object at 0x7e6111aa2c80> Application
schneider-electric ecostruxure_power_monitoring_expert 2021 <built-in method update of dict object at 0x7e6111aace00> Application
schneider-electric ecostruxure_power_monitoring_expert 2021 <built-in method update of dict object at 0x7e6111aaeec0> Application

Affected Configurations

Operator: OR

Vulnerable CPE
Yes cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2020:-:*:*:*:*:*:*
Yes cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2020:cumulative_update_1:*:*:*:*:*:*
Yes cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2020:cumulative_update_2:*:*:*:*:*:*
Yes cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2021:-:*:*:*:*:*:*
Yes cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:2021:cumulative_update_1:*:*:*:*:*:*
Notification
Message here