IM
IronMonkey Threat Research

CVE-2023-37553 MEDIUM

Published: 2023-08-03 | Last Modified: 2024-11-21 | Status: Modified

Description

In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37554, CVE-2023-37555 and CVE-2023-37556.

Additional Descriptions (1)

En múltiples versiones de múltiples productos de Codesys, después de una autenticación exitosa como usuario, las solicitudes de comunicación de red con contenido inconsistente pueden causar que el componente CmpAppBP lea internamente desde una dirección inválida, potencialmente llevando a una condición de denegación de servicio. Esta vulnerabilidad es diferente de CVE-2023-37552, CVE-2023-37554, CVE-2023-37555 y CVE-2023-37556.

CVSS Metrics

Base Score: 6.5 (MEDIUM)

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H

Attack VectorNETWORK
Attack ComplexityLOW
Privileges RequiredLOW
User InteractionNONE
ScopeUNCHANGED
Confidentiality ImpactNONE
Integrity ImpactNONE
Availability ImpactHIGH

Source: [email protected]

Type: Secondary

Exploitability Score: 2.8

Impact Score: 3.6

Weaknesses

Source Type Description
[email protected] Secondary
en CWE-20
[email protected] Primary
en NVD-CWE-noinfo

Affected Products

Vendor Product Version Update Type
codesys control_for_beaglebone_sl * <built-in method update of dict object at 0x7e60e8c7df00> Application
codesys control_for_empc-a\/imx6_sl * <built-in method update of dict object at 0x7e60e8c7de40> Application
codesys control_for_iot2000_sl * <built-in method update of dict object at 0x7e60e8c7d740> Application
codesys control_for_linux_sl * <built-in method update of dict object at 0x7e6108404380> Application
codesys control_for_pfc100_sl * <built-in method update of dict object at 0x7e60e8c7fb40> Application
codesys control_for_pfc200_sl * <built-in method update of dict object at 0x7e60e8c7d180> Application
codesys control_for_plcnext_sl * <built-in method update of dict object at 0x7e60e8c7db00> Application
codesys control_for_raspberry_pi_sl * <built-in method update of dict object at 0x7e60e8c7c400> Application
codesys control_for_wago_touch_panels_600_sl * <built-in method update of dict object at 0x7e60e8c7c580> Application
codesys control_rte_sl * <built-in method update of dict object at 0x7e60e8c7f300> Application
codesys control_rte_sl_\(for_beckhoff_cx\) * <built-in method update of dict object at 0x7e60e8c7dc80> Application
codesys control_runtime_system_toolkit * <built-in method update of dict object at 0x7e60e8c7ed40> Application
codesys control_win_sl * <built-in method update of dict object at 0x7e60a88adc40> Application
codesys development_system * <built-in method update of dict object at 0x7e613c341100> Application
codesys hmi * <built-in method update of dict object at 0x7e60e8c7f800> Application
codesys safety_sil2 * <built-in method update of dict object at 0x7e6111c1dd80> Application

Affected Configurations

Operator: OR

Vulnerable CPE
Yes cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*
Yes cpe:2.3:a:codesys:control_for_empc-a\/imx6_sl:*:*:*:*:*:*:*:*
Yes cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*
Yes cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*
Yes cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*
Yes cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*
Yes cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*
Yes cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*
Yes cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*

Operator: OR

Vulnerable CPE
Yes cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*
Yes cpe:2.3:a:codesys:control_rte_sl_\(for_beckhoff_cx\):*:*:*:*:*:*:*:*
Yes cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*
Yes cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*
Yes cpe:2.3:a:codesys:development_system:*:*:*:*:*:*:*:*
Yes cpe:2.3:a:codesys:hmi:*:*:*:*:*:*:*:*
Yes cpe:2.3:a:codesys:safety_sil2:*:*:*:*:*:*:*:*

References

Notification
Message here