A CWE-89: Improper Neutralization of Special Elements used in SQL Command (‘SQL Injection’) vulnerability exists that allows adversaries with local user privileges to craft a malicious SQL query and execute as part of project migration which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior).
Existe una vulnerabilidad CWE-89: Neutralización inadecuada de elementos especiales utilizados en el comando SQL ('Inyección SQL') que permite a adversarios con privilegios de usuario local crear una consulta SQL maliciosa y ejecutarla como parte de la migración del proyecto, lo que podría resultar en la ejecución de código malicioso. Productos afectados: EcoStruxure Operator Terminal Expert (V3.3 Hotfix 1 o anterior), Pro-face BLUE (V3.3 Hotfix 1 o anterior).
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
| Attack Vector | LOCAL |
|---|---|
| Attack Complexity | LOW |
| Privileges Required | LOW |
| User Interaction | NONE |
| Scope | UNCHANGED |
| Confidentiality Impact | HIGH |
| Integrity Impact | HIGH |
| Availability Impact | HIGH |
| Source | Type | Description |
|---|---|---|
| [email protected] | Secondary |
en
CWE-89
|
| Vendor | Product | Version | Update | Type |
|---|---|---|---|---|
| schneider-electric | ecostruxure_operator_terminal_expert | * | <built-in method update of dict object at 0x7e6111c1c880> | Application |
| schneider-electric | ecostruxure_operator_terminal_expert | 3.3 | <built-in method update of dict object at 0x7e60e8c7cc00> | Application |
| schneider-electric | ecostruxure_operator_terminal_expert | 3.3 | <built-in method update of dict object at 0x7e6108405940> | Application |
| schneider-electric | pro-face_blue | * | <built-in method update of dict object at 0x7e61419fc240> | Application |
| schneider-electric | pro-face_blue | 3.3 | <built-in method update of dict object at 0x7e6111c1da80> | Application |
| schneider-electric | pro-face_blue | 3.3 | <built-in method update of dict object at 0x7e6111c1fb00> | Application |
| Vulnerable | CPE |
|---|---|
| Yes | cpe:2.3:a:schneider-electric:ecostruxure_operator_terminal_expert:*:*:*:*:*:*:*:* |
| Yes | cpe:2.3:a:schneider-electric:ecostruxure_operator_terminal_expert:3.3:-:*:*:*:*:*:* |
| Yes | cpe:2.3:a:schneider-electric:ecostruxure_operator_terminal_expert:3.3:hotfix1:*:*:*:*:*:* |
| Yes | cpe:2.3:a:schneider-electric:pro-face_blue:*:*:*:*:*:*:*:* |
| Yes | cpe:2.3:a:schneider-electric:pro-face_blue:3.3:-:*:*:*:*:*:* |
| Yes | cpe:2.3:a:schneider-electric:pro-face_blue:3.3:hotfix1:*:*:*:*:*:* |