IM
IronMonkey Threat Research

CVE-2022-41670 HIGH

Published: 2022-11-04 | Last Modified: 2024-11-21 | Status: Modified

Description

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in the SGIUtility component that allows adversaries with local user privileges to load malicious DLL which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior).

Additional Descriptions (1)

Existe una vulnerabilidad CWE-22: Limitación Inadecuada de un Nombre de Ruta a un Directorio Restringido ("Path Traversal") en el componente SGIUtility que permite a adversarios con privilegios de usuario local cargar archivos DLL maliciosos que podrían resultar en la ejecución de código malicioso. Productos afectados: EcoStruxure Operator Terminal Expert (V3.3 Hotfix 1 o anterior), Pro-face BLUE (V3.3 Hotfix 1 o anterior).

CVSS Metrics

Base Score: 7.8 (HIGH)

CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Attack VectorLOCAL
Attack ComplexityLOW
Privileges RequiredLOW
User InteractionNONE
ScopeUNCHANGED
Confidentiality ImpactHIGH
Integrity ImpactHIGH
Availability ImpactHIGH

Source: [email protected]

Type: Primary

Exploitability Score: 1.8

Impact Score: 5.9

Weaknesses

Source Type Description
[email protected] Secondary
en CWE-22

Affected Products

Vendor Product Version Update Type
schneider-electric ecostruxure_operator_terminal_expert * <built-in method update of dict object at 0x7e60a8895d00> Application
schneider-electric ecostruxure_operator_terminal_expert 3.3 <built-in method update of dict object at 0x7e60bacd55c0> Application
schneider-electric ecostruxure_operator_terminal_expert 3.3 <built-in method update of dict object at 0x7e61109d69c0> Application
schneider-electric pro-face_blue * <built-in method update of dict object at 0x7e61109d67c0> Application
schneider-electric pro-face_blue 3.3 <built-in method update of dict object at 0x7e60a8897f80> Application
schneider-electric pro-face_blue 3.3 <built-in method update of dict object at 0x7e6108404980> Application

Affected Configurations

Operator: OR

Vulnerable CPE
Yes cpe:2.3:a:schneider-electric:ecostruxure_operator_terminal_expert:*:*:*:*:*:*:*:*
Yes cpe:2.3:a:schneider-electric:ecostruxure_operator_terminal_expert:3.3:-:*:*:*:*:*:*
Yes cpe:2.3:a:schneider-electric:ecostruxure_operator_terminal_expert:3.3:hotfix1:*:*:*:*:*:*
Yes cpe:2.3:a:schneider-electric:pro-face_blue:*:*:*:*:*:*:*:*
Yes cpe:2.3:a:schneider-electric:pro-face_blue:3.3:-:*:*:*:*:*:*
Yes cpe:2.3:a:schneider-electric:pro-face_blue:3.3:hotfix1:*:*:*:*:*:*

References

Notification
Message here