CVE-2022-24319 MEDIUM

Published: 2022-02-09 | Last Modified: 2024-11-21 | Status: Modified

Description

A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA web server are intercepted. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)

Additional Descriptions (1)

Una CWE-295: Se presenta una vulnerabilidad de Comprobación de Certificados inapropiada que podría permitir un ataque de tipo Man-in-theMiddle cuando son interceptadas las comunicaciones entre el cliente y el servidor web de Geo SCADA. Producto afectado: ClearSCADA (todas las versiones), EcoStruxure Geo SCADA Expert 2019 (todas las versiones), EcoStruxure Geo SCADA Expert 2020 (todas las versiones)

CVSS Metrics

Base Score: 5.9 (MEDIUM)

CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N

Attack VectorNETWORK
Attack ComplexityHIGH
Privileges RequiredNONE
User InteractionNONE
ScopeUNCHANGED
Confidentiality ImpactHIGH
Integrity ImpactNONE
Availability ImpactNONE

Source: [email protected]

Type: Primary

Exploitability Score: 2.2

Impact Score: 3.6

Base Score: 4.3 (MEDIUM)

AV:N/AC:M/Au:N/C:P/I:N/A:N

Access VectorNETWORK
Access ComplexityMEDIUM
AuthenticationNONE
Confidentiality ImpactPARTIAL
Integrity ImpactNONE
Availability ImpactNONE

Source: [email protected]

Type: Primary

Exploitability Score: 8.6

Impact Score: 2.9

Weaknesses

Source Type Description
[email protected] Secondary
en CWE-295
[email protected] Primary
en CWE-295

Affected Products

Vendor Product Version Update Type
schneider-electric clearscada - <built-in method update of dict object at 0x7e60a88354c0> Application
schneider-electric ecostruxure_geo_scada_expert_2019 * <built-in method update of dict object at 0x7e6107f39d40> Application
schneider-electric ecostruxure_geo_scada_expert_2020 * <built-in method update of dict object at 0x7e6107f38600> Application

Affected Configurations

Operator: OR

Vulnerable CPE
Yes cpe:2.3:a:schneider-electric:clearscada:-:*:*:*:*:*:*:*
Yes cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2019:*:*:*:*:*:*:*:*
Yes cpe:2.3:a:schneider-electric:ecostruxure_geo_scada_expert_2020:*:*:*:*:*:*:*:*
Notification