A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause a web session compromise when an attacker injects and then executes arbitrary malicious JavaScript code inside the target browser. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)
Una CWE-79: Se presenta una vulnerabilidad de Neutralización Inadecuada de Entradas Durante la Generación de Páginas Web ("Cross-site Scripting") que podría causar un compromiso de la sesión web cuando un atacante inyecta y luego ejecuta código JavaScript malicioso arbitrario dentro del navegador de destino. Producto afectado: spaceLYnk (versiones V2.6.2 y anteriores), Wiser for KNX (anteriormente homeLYnk) (versiones V2.6.2 y anteriores), fellerLYnk (V2.6.2 y anteriores)
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
| Attack Vector | NETWORK |
|---|---|
| Attack Complexity | LOW |
| Privileges Required | NONE |
| User Interaction | REQUIRED |
| Scope | CHANGED |
| Confidentiality Impact | LOW |
| Integrity Impact | LOW |
| Availability Impact | NONE |
AV:N/AC:M/Au:N/C:N/I:P/A:N
| Access Vector | NETWORK |
|---|---|
| Access Complexity | MEDIUM |
| Authentication | NONE |
| Confidentiality Impact | NONE |
| Integrity Impact | PARTIAL |
| Availability Impact | NONE |
| Source | Type | Description |
|---|---|---|
| [email protected] | Secondary |
en
CWE-79
|
| Vendor | Product | Version | Update | Type |
|---|---|---|---|---|
| schneider-electric | spacelynk_firmware | * | <built-in method update of dict object at 0x7e611224dd40> | Operating System |
| schneider-electric | wiser_for_knx_firmware | * | <built-in method update of dict object at 0x7e60ba2a77c0> | Operating System |
| schneider-electric | fellerlynk_firmware | * | <built-in method update of dict object at 0x7e613cfc3b80> | Operating System |
| Vulnerable | CPE |
|---|---|
| Yes | cpe:2.3:o:schneider-electric:spacelynk_firmware:*:*:*:*:*:*:*:* |
| Vulnerable | CPE |
|---|---|
| No | cpe:2.3:h:schneider-electric:spacelynk:-:*:*:*:*:*:*:* |
| Vulnerable | CPE |
|---|---|
| Yes | cpe:2.3:o:schneider-electric:wiser_for_knx_firmware:*:*:*:*:*:*:*:* |
| Vulnerable | CPE |
|---|---|
| No | cpe:2.3:h:schneider-electric:wiser_for_knx:-:*:*:*:*:*:*:* |
| Vulnerable | CPE |
|---|---|
| Yes | cpe:2.3:o:schneider-electric:fellerlynk_firmware:*:*:*:*:*:*:*:* |
| Vulnerable | CPE |
|---|---|
| No | cpe:2.3:h:schneider-electric:fellerlynk:-:*:*:*:*:*:*:* |