IM
IronMonkey Threat Research

CVE-2021-22797 HIGH

Published: 2022-04-13 | Last Modified: 2024-11-21 | Status: Modified

Description

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including former Unity Pro), EcoStruxure Process Expert (2020 and prior, including former HDCS), SCADAPack RemoteConnect for x70 (All versions)

Additional Descriptions (1)

Una CWE-22: Se presenta una vulnerabilidad de Limitación inadecuada de un nombre de ruta a un directorio restringido (" Salto de Ruta") que podría causar la implementación de scripts maliciosos en una ubicación no autorizada y puede resultar en una ejecución de código en la estación de trabajo de ingeniería cuando es cargado un archivo de proyecto malicioso en el software de ingeniería. Producto afectado: EcoStruxure Control Expert (versiones V15.0 SP1 y anteriores, incluido el antiguo Unity Pro), EcoStruxure Process Expert (versiones 2020 y anteriores, incluido el antiguo HDCS), SCADAPack RemoteConnect para x70 (Todas las versiones)

CVSS Metrics

Base Score: 7.8 (HIGH)

CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Attack VectorLOCAL
Attack ComplexityLOW
Privileges RequiredNONE
User InteractionREQUIRED
ScopeUNCHANGED
Confidentiality ImpactHIGH
Integrity ImpactHIGH
Availability ImpactHIGH

Source: [email protected]

Type: Primary

Exploitability Score: 1.8

Impact Score: 5.9

Base Score: 9.3 (HIGH)

AV:N/AC:M/Au:N/C:C/I:C/A:C

Access VectorNETWORK
Access ComplexityMEDIUM
AuthenticationNONE
Confidentiality ImpactCOMPLETE
Integrity ImpactCOMPLETE
Availability ImpactCOMPLETE

Source: [email protected]

Type: Primary

Exploitability Score: 8.6

Impact Score: 10.0

Weaknesses

Source Type Description
[email protected] Secondary
en CWE-22

Affected Products

Vendor Product Version Update Type
schneider-electric ecostruxure_control_expert * <built-in method update of dict object at 0x7e60ba2a5ac0> Application
schneider-electric ecostruxure_process_expert * <built-in method update of dict object at 0x7e60ba2a77c0> Application
schneider-electric remoteconnect - <built-in method update of dict object at 0x7e6111dd1540> Application

Affected Configurations

Operator: OR

Vulnerable CPE
Yes cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*
Yes cpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:*

Operator: OR

Vulnerable CPE
Yes cpe:2.3:a:schneider-electric:remoteconnect:-:*:*:*:*:*:*:*

Operator: OR

Vulnerable CPE
No cpe:2.3:h:schneider-electric:scadapack_470:-:*:*:*:*:*:*:*
No cpe:2.3:h:schneider-electric:scadapack_474:-:*:*:*:*:*:*:*
No cpe:2.3:h:schneider-electric:scadapack_570:-:*:*:*:*:*:*:*
No cpe:2.3:h:schneider-electric:scadapack_574:-:*:*:*:*:*:*:*
No cpe:2.3:h:schneider-electric:scadapack_575:-:*:*:*:*:*:*:*

References

Notification
Message here