A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including former Unity Pro), EcoStruxure Process Expert (2020 and prior, including former HDCS), SCADAPack RemoteConnect for x70 (All versions)
Una CWE-22: Se presenta una vulnerabilidad de Limitación inadecuada de un nombre de ruta a un directorio restringido (" Salto de Ruta") que podría causar la implementación de scripts maliciosos en una ubicación no autorizada y puede resultar en una ejecución de código en la estación de trabajo de ingeniería cuando es cargado un archivo de proyecto malicioso en el software de ingeniería. Producto afectado: EcoStruxure Control Expert (versiones V15.0 SP1 y anteriores, incluido el antiguo Unity Pro), EcoStruxure Process Expert (versiones 2020 y anteriores, incluido el antiguo HDCS), SCADAPack RemoteConnect para x70 (Todas las versiones)
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
| Attack Vector | LOCAL |
|---|---|
| Attack Complexity | LOW |
| Privileges Required | NONE |
| User Interaction | REQUIRED |
| Scope | UNCHANGED |
| Confidentiality Impact | HIGH |
| Integrity Impact | HIGH |
| Availability Impact | HIGH |
AV:N/AC:M/Au:N/C:C/I:C/A:C
| Access Vector | NETWORK |
|---|---|
| Access Complexity | MEDIUM |
| Authentication | NONE |
| Confidentiality Impact | COMPLETE |
| Integrity Impact | COMPLETE |
| Availability Impact | COMPLETE |
| Source | Type | Description |
|---|---|---|
| [email protected] | Secondary |
en
CWE-22
|
| Vendor | Product | Version | Update | Type |
|---|---|---|---|---|
| schneider-electric | ecostruxure_control_expert | * | <built-in method update of dict object at 0x7e60ba2a5ac0> | Application |
| schneider-electric | ecostruxure_process_expert | * | <built-in method update of dict object at 0x7e60ba2a77c0> | Application |
| schneider-electric | remoteconnect | - | <built-in method update of dict object at 0x7e6111dd1540> | Application |
| Vulnerable | CPE |
|---|---|
| Yes | cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:* |
| Yes | cpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:* |
| Vulnerable | CPE |
|---|---|
| Yes | cpe:2.3:a:schneider-electric:remoteconnect:-:*:*:*:*:*:*:* |
| Vulnerable | CPE |
|---|---|
| No | cpe:2.3:h:schneider-electric:scadapack_470:-:*:*:*:*:*:*:* |
| No | cpe:2.3:h:schneider-electric:scadapack_474:-:*:*:*:*:*:*:* |
| No | cpe:2.3:h:schneider-electric:scadapack_570:-:*:*:*:*:*:*:* |
| No | cpe:2.3:h:schneider-electric:scadapack_574:-:*:*:*:*:*:*:* |
| No | cpe:2.3:h:schneider-electric:scadapack_575:-:*:*:*:*:*:*:* |