Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause unauthorized access to a project file protected by a password when this file is shared with untrusted sources. An attacker may bypass the password protection and be able to view and modify a project file.
Se presenta una vulnerabilidad de Credenciales Insuficientemente Protegidas en EcoStruxure Control Expert (todas las versiones anteriores a V15.0 SP1, incluyendo todas las versiones de Unity Pro), EcoStruxure Process Expert (todas las versiones, incluyendo todas las versiones de EcoStruxure Hybrid DCS), y SCADAPack RemoteConnect for x70, todas las versiones, que podría causar un acceso no autorizado a un archivo de proyecto protegido por una contraseña cuando este archivo se comparte con fuentes no confiables. Un atacante podría omitir la protección por contraseña y ser capaz de visualizar y modificar un archivo de proyecto
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N
| Attack Vector | LOCAL |
|---|---|
| Attack Complexity | LOW |
| Privileges Required | LOW |
| User Interaction | NONE |
| Scope | UNCHANGED |
| Confidentiality Impact | HIGH |
| Integrity Impact | HIGH |
| Availability Impact | NONE |
AV:L/AC:L/Au:N/C:P/I:P/A:N
| Access Vector | LOCAL |
|---|---|
| Access Complexity | LOW |
| Authentication | NONE |
| Confidentiality Impact | PARTIAL |
| Integrity Impact | PARTIAL |
| Availability Impact | NONE |
| Source | Type | Description |
|---|---|---|
| [email protected] | Secondary |
en
CWE-522
|
| Vendor | Product | Version | Update | Type |
|---|---|---|---|---|
| schneider-electric | ecostruxure_control_expert | * | <built-in method update of dict object at 0x7e60e8341440> | Application |
| schneider-electric | ecostruxure_control_expert | 15.0 | <built-in method update of dict object at 0x7e6071eac940> | Application |
| schneider-electric | ecostruxure_process_expert | * | <built-in method update of dict object at 0x7e6071eae380> | Application |
| schneider-electric | remoteconnect | * | <built-in method update of dict object at 0x7e60ba9bf9c0> | Application |
| Vulnerable | CPE |
|---|---|
| Yes | cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:* |
| Yes | cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.0:-:*:*:*:*:*:* |
| Yes | cpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:* |
| Yes | cpe:2.3:a:schneider-electric:remoteconnect:*:*:*:*:*:*:scadapack_x70:* |