A CWE-759: Use of a One-Way Hash without a Salt vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could lead an attacker to get knowledge of charging station user account credentials using dictionary attacks techniques.
A CWE-759: Se presenta una vulnerabilidad de Uso de un Hash Unidireccional sin Salt en EVlink City (EVC1S22P4 / EVC1S7P4 todas las versiones anteriores a R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 todas las versiones anteriores a R8 V3.4.0.1), y EVlink Smart Wallbox (EVB1A todas las versiones anteriores a R8 V3.4.0.1) que podría conllevar a un atacante a obtener conocimiento de las credenciales de la cuenta de usuario de la estación de carga usando técnicas de ataque de diccionario
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
| Attack Vector | NETWORK |
|---|---|
| Attack Complexity | LOW |
| Privileges Required | NONE |
| User Interaction | NONE |
| Scope | UNCHANGED |
| Confidentiality Impact | HIGH |
| Integrity Impact | NONE |
| Availability Impact | NONE |
AV:N/AC:L/Au:N/C:P/I:N/A:N
| Access Vector | NETWORK |
|---|---|
| Access Complexity | LOW |
| Authentication | NONE |
| Confidentiality Impact | PARTIAL |
| Integrity Impact | NONE |
| Availability Impact | NONE |
| Source | Type | Description |
|---|---|---|
| [email protected] | Primary |
en
CWE-916
|
| Vendor | Product | Version | Update | Type |
|---|---|---|---|---|
| schneider-electric | evlink_city_evc1s22p4_firmware | * | <built-in method update of dict object at 0x7e60e8815700> | Operating System |
| schneider-electric | evlink_city_evc1s7p4_firmware | * | <built-in method update of dict object at 0x7e61109d5bc0> | Operating System |
| schneider-electric | evlink_parking_evw2_firmware | * | <built-in method update of dict object at 0x7e60eb24d6c0> | Operating System |
| schneider-electric | evlink_parking_evf2_firmware | * | <built-in method update of dict object at 0x7e60e884f100> | Operating System |
| schneider-electric | evlink_parking_ev.2_firmware | * | <built-in method update of dict object at 0x7e60e88159c0> | Operating System |
| schneider-electric | evlink_smart_wallbox_evb1a_firmware | * | <built-in method update of dict object at 0x7e60e884f3c0> | Operating System |
| Vulnerable | CPE |
|---|---|
| Yes | cpe:2.3:o:schneider-electric:evlink_city_evc1s22p4_firmware:*:*:*:*:*:*:*:* |
| Vulnerable | CPE |
|---|---|
| No | cpe:2.3:h:schneider-electric:evlink_city_evc1s22p4:-:*:*:*:*:*:*:* |
| Vulnerable | CPE |
|---|---|
| Yes | cpe:2.3:o:schneider-electric:evlink_city_evc1s7p4_firmware:*:*:*:*:*:*:*:* |
| Vulnerable | CPE |
|---|---|
| No | cpe:2.3:h:schneider-electric:evlink_city_evc1s7p4:-:*:*:*:*:*:*:* |
| Vulnerable | CPE |
|---|---|
| Yes | cpe:2.3:o:schneider-electric:evlink_parking_evw2_firmware:*:*:*:*:*:*:*:* |
| Vulnerable | CPE |
|---|---|
| No | cpe:2.3:h:schneider-electric:evlink_parking_evw2:-:*:*:*:*:*:*:* |
| Vulnerable | CPE |
|---|---|
| Yes | cpe:2.3:o:schneider-electric:evlink_parking_evf2_firmware:*:*:*:*:*:*:*:* |
| Vulnerable | CPE |
|---|---|
| No | cpe:2.3:h:schneider-electric:evlink_parking_evf2:-:*:*:*:*:*:*:* |
| Vulnerable | CPE |
|---|---|
| Yes | cpe:2.3:o:schneider-electric:evlink_parking_ev.2_firmware:*:*:*:*:*:*:*:* |
| Vulnerable | CPE |
|---|---|
| No | cpe:2.3:h:schneider-electric:evlink_parking_ev.2:-:*:*:*:*:*:*:* |
| Vulnerable | CPE |
|---|---|
| Yes | cpe:2.3:o:schneider-electric:evlink_smart_wallbox_evb1a_firmware:*:*:*:*:*:*:*:* |
| Vulnerable | CPE |
|---|---|
| No | cpe:2.3:h:schneider-electric:evlink_smart_wallbox_evb1a:-:*:*:*:*:*:*:* |