Description

A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0), which could cause the meter to reboot or allow for remote code execution.

Additional Descriptions (1)

A CWE-119: se presenta una vulnerabilidad de Restricción Inapropiada de Operaciones dentro de los Límites de un Búfer de la Memoria en PowerLogic ION7400, PM8000 e ION9000 (todas las versiones anteriores a V3.0.0), lo que podría causar al medidor reiniciarse o permitir una ejecución de código remota

CVSS Metrics

Base Score: 9.8 (CRITICAL)

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Attack VectorNETWORK
Attack ComplexityLOW
Privileges RequiredNONE
User InteractionNONE
ScopeUNCHANGED
Confidentiality ImpactHIGH
Integrity ImpactHIGH
Availability ImpactHIGH

Source: [email protected]

Type: Primary

Exploitability Score: 3.9

Impact Score: 5.9

Base Score: 7.5 (HIGH)

AV:N/AC:L/Au:N/C:P/I:P/A:P

Access VectorNETWORK
Access ComplexityLOW
AuthenticationNONE
Confidentiality ImpactPARTIAL
Integrity ImpactPARTIAL
Availability ImpactPARTIAL

Source: [email protected]

Type: Primary

Exploitability Score: 10.0

Impact Score: 6.4

Weaknesses

Source Type Description
[email protected] Secondary
en CWE-119

Affected Products

Vendor Product Version Update Type
schneider-electric powerlogic_ion7400_firmware * <built-in method update of dict object at 0x7e60baa0a340> Operating System
schneider-electric powerlogic_pm8000_firmware * <built-in method update of dict object at 0x7e60bae0e480> Operating System
schneider-electric powerlogic_ion9000_firmware * <built-in method update of dict object at 0x7e60b81014c0> Operating System

Affected Configurations

Operator: OR

Vulnerable CPE
Yes cpe:2.3:o:schneider-electric:powerlogic_ion7400_firmware:*:*:*:*:*:*:*:*

Operator: OR

Vulnerable CPE
No cpe:2.3:h:schneider-electric:powerlogic_ion7400:-:*:*:*:*:*:*:*

Operator: OR

Vulnerable CPE
Yes cpe:2.3:o:schneider-electric:powerlogic_pm8000_firmware:*:*:*:*:*:*:*:*

Operator: OR

Vulnerable CPE
No cpe:2.3:h:schneider-electric:powerlogic_pm8000:-:*:*:*:*:*:*:*

Operator: OR

Vulnerable CPE
Yes cpe:2.3:o:schneider-electric:powerlogic_ion9000_firmware:*:*:*:*:*:*:*:*

Operator: OR

Vulnerable CPE
No cpe:2.3:h:schneider-electric:powerlogic_ion9000:-:*:*:*:*:*:*:*

References

Notification
Message here