A CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to gain full access by brute force.

Additional Descriptions (1)

Una CWE-307: Se presenta una vulnerabilidad de Restricción Inapropiada de Intentos de Autenticación Excesiva en Easergy T300 (versiones de Firmware 1.5.2 y anteriores) que podría permitir a un atacante conseguir acceso total mediante fuerza bruta

CVSS Metrics

Base Score: 9.8 (CRITICAL)

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Attack VectorNETWORK
Attack ComplexityLOW
Privileges RequiredNONE
User InteractionNONE
ScopeUNCHANGED
Confidentiality ImpactHIGH
Integrity ImpactHIGH
Availability ImpactHIGH

Source: [email protected]

Type: Primary

Exploitability Score: 3.9

Impact Score: 5.9

Base Score: 5.0 (MEDIUM)

AV:N/AC:L/Au:N/C:P/I:N/A:N

Access VectorNETWORK
Access ComplexityLOW
AuthenticationNONE
Confidentiality ImpactPARTIAL
Integrity ImpactNONE
Availability ImpactNONE

Source: [email protected]

Type: Primary

Exploitability Score: 10.0

Impact Score: 2.9

Weaknesses

Source Type Description
[email protected] Secondary
en CWE-307
[email protected] Primary
en CWE-307

Affected Products

Vendor Product Version Update Type
schneider-electric easergy_t300_firmware * <built-in method update of dict object at 0x7e6108406000> Operating System

Affected Configurations

Operator: OR

Vulnerable CPE
Yes cpe:2.3:o:schneider-electric:easergy_t300_firmware:*:*:*:*:*:*:*:*

Operator: OR

Vulnerable CPE
No cpe:2.3:h:schneider-electric:easergy_t300:-:*:*:*:*:*:*:*