Description

A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10), which, if exploited, could allow attackers to transfer malicious code to the controller.

Additional Descriptions (1)

Una CWE-74: Una Neutralización Inapropiada de Elementos Especiales en la Salida Usada por un Componente Aguas Abajo ("Inyection"), una DLL reflexiva, la vulnerabilidad se presenta en EcoStruxure Control Expert (todas las versiones anteriores a 14.1 Hot Fix), Unity Pro (todas las versiones), Modicon M340 (todas las versiones anteriores a V3.20), Modicon M580 (todas las versiones anteriores a V3.10), que, si es explotada, podría permitir a atacantes transferir códigos maliciosos hacia el controlador.

CVSS Metrics

Base Score: 9.8 (CRITICAL)

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Attack VectorNETWORK
Attack ComplexityLOW
Privileges RequiredNONE
User InteractionNONE
ScopeUNCHANGED
Confidentiality ImpactHIGH
Integrity ImpactHIGH
Availability ImpactHIGH

Source: [email protected]

Type: Primary

Exploitability Score: 3.9

Impact Score: 5.9

Base Score: 7.5 (HIGH)

AV:N/AC:L/Au:N/C:P/I:P/A:P

Access VectorNETWORK
Access ComplexityLOW
AuthenticationNONE
Confidentiality ImpactPARTIAL
Integrity ImpactPARTIAL
Availability ImpactPARTIAL

Source: [email protected]

Type: Primary

Exploitability Score: 10.0

Impact Score: 6.4

Weaknesses

Source Type Description
[email protected] Secondary
en CWE-74
[email protected] Primary
en CWE-74

Affected Products

Vendor Product Version Update Type
schneider-electric ecostruxure_control_expert * <built-in method update of dict object at 0x7e60baa343c0> Application
schneider-electric unity_pro * <built-in method update of dict object at 0x7e60baa34e00> Application
schneider-electric modicon_m340_firmware * <built-in method update of dict object at 0x7e60e86cf300> Operating System
schneider-electric modicon_m580_firmware * <built-in method update of dict object at 0x7e6110f05140> Operating System

Affected Configurations

Operator: OR

Vulnerable CPE
Yes cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*
Yes cpe:2.3:a:schneider-electric:unity_pro:*:*:*:*:*:*:*:*

Operator: OR

Vulnerable CPE
Yes cpe:2.3:o:schneider-electric:modicon_m340_firmware:*:*:*:*:*:*:*:*

Operator: OR

Vulnerable CPE
No cpe:2.3:h:schneider-electric:modicon_m340:-:*:*:*:*:*:*:*

Operator: OR

Vulnerable CPE
Yes cpe:2.3:o:schneider-electric:modicon_m580_firmware:*:*:*:*:*:*:*:*

Operator: OR

Vulnerable CPE
No cpe:2.3:h:schneider-electric:modicon_m580:-:*:*:*:*:*:*:*

References

Notification
Message here