IM
IronMonkey Threat Research

CVE-2019-6848 HIGH

Published: 2019-10-29 | Last Modified: 2024-11-21 | Status: Modified

Description

A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 CPU (BMEx58*) and Modicon M580 communication module (BMENOC0311, BMENOC0321) (see notification for version info), which could cause a Denial of Service attack on the PLC when sending specific data on the REST API of the controller/communication module.

Additional Descriptions (1)

Existe una vulnerabilidad CWE-755: Manejo inadecuado de condiciones excepcionales en la CPU Modicon M580 (BMEx58*) y en el módulo de comunicación Modicon M580 (BMENOC0311, BMENOC0321) (consulte la notificación para obtener información sobre la versión), que podría provocar un ataque de denegación de servicio en el PLC al enviar datos específicos en la API REST del controlador/módulo de comunicación

CVSS Metrics

Base Score: 8.6 (HIGH)

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H

Attack VectorNETWORK
Attack ComplexityLOW
Privileges RequiredNONE
User InteractionNONE
ScopeCHANGED
Confidentiality ImpactNONE
Integrity ImpactNONE
Availability ImpactHIGH

Source: [email protected]

Type: Primary

Exploitability Score: 3.9

Impact Score: 4.0

Base Score: 5.0 (MEDIUM)

AV:N/AC:L/Au:N/C:N/I:N/A:P

Access VectorNETWORK
Access ComplexityLOW
AuthenticationNONE
Confidentiality ImpactNONE
Integrity ImpactNONE
Availability ImpactPARTIAL

Source: [email protected]

Type: Primary

Exploitability Score: 10.0

Impact Score: 2.9

Weaknesses

Source Type Description
[email protected] Secondary
en CWE-755
[email protected] Primary
en CWE-755

Affected Products

Vendor Product Version Update Type
schneider-electric modicon_m580_firmware - <built-in method update of dict object at 0x7e60eb226c80> Operating System
schneider-electric modicon_bmenoc_0311_firmware - <built-in method update of dict object at 0x7e60a88af180> Operating System
schneider-electric modicon_bmenoc_0321_firmware - <built-in method update of dict object at 0x7e60eb225580> Operating System

Affected Configurations

Operator: OR

Vulnerable CPE
Yes cpe:2.3:o:schneider-electric:modicon_m580_firmware:-:*:*:*:*:*:*:*

Operator: OR

Vulnerable CPE
No cpe:2.3:h:schneider-electric:modicon_m580:-:*:*:*:*:*:*:*

Operator: OR

Vulnerable CPE
Yes cpe:2.3:o:schneider-electric:modicon_bmenoc_0311_firmware:-:*:*:*:*:*:*:*

Operator: OR

Vulnerable CPE
No cpe:2.3:h:schneider-electric:modicon_bmenoc_0311:-:*:*:*:*:*:*:*

Operator: OR

Vulnerable CPE
Yes cpe:2.3:o:schneider-electric:modicon_bmenoc_0321_firmware:-:*:*:*:*:*:*:*

Operator: OR

Vulnerable CPE
No cpe:2.3:h:schneider-electric:modicon_bmenoc_0321:-:*:*:*:*:*:*:*
Notification
Message here