A CWE-755: Improper Handling of Exceptional Conditions vulnerability exists in Modicon M580 with firmware (version prior to V3.10), Modicon M340 (all firmware versions), and Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause a Denial of Service attack on the PLC when upgrading the controller with an empty firmware package using FTP protocol.
Existe una vulnerabilidad CWE-755: Manejo inadecuado de condiciones excepcionales en Modicon M580 con firmware (versión anterior a V3.10), Modicon M340 (todas las versiones de firmware) y módulos Modicon BMxCRA y 140CRA (todas las versiones de firmware), que podría causar un ataque de denegación de servicio en el PLC al actualizar el controlador con un paquete de firmware vacío utilizando el protocolo FTP
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H
| Attack Vector | NETWORK |
|---|---|
| Attack Complexity | LOW |
| Privileges Required | HIGH |
| User Interaction | NONE |
| Scope | UNCHANGED |
| Confidentiality Impact | NONE |
| Integrity Impact | NONE |
| Availability Impact | HIGH |
AV:N/AC:L/Au:S/C:N/I:N/A:P
| Access Vector | NETWORK |
|---|---|
| Access Complexity | LOW |
| Authentication | SINGLE |
| Confidentiality Impact | NONE |
| Integrity Impact | NONE |
| Availability Impact | PARTIAL |
| Source | Type | Description |
|---|---|---|
| [email protected] | Secondary |
en
CWE-755
|
| [email protected] | Primary |
en
CWE-755
|
| Vendor | Product | Version | Update | Type |
|---|---|---|---|---|
| schneider-electric | modicon_m580_firmware | * | <built-in method update of dict object at 0x7e60baa0a040> | Operating System |
| schneider-electric | modicon_m340_firmware | * | <built-in method update of dict object at 0x7e6110c9ae00> | Operating System |
| schneider-electric | modicon_bmxcra_firmware | * | <built-in method update of dict object at 0x7e610746b540> | Operating System |
| schneider-electric | modicon_140cra_firmware | * | <built-in method update of dict object at 0x7e60e8874f00> | Operating System |
| Vulnerable | CPE |
|---|---|
| Yes | cpe:2.3:o:schneider-electric:modicon_m580_firmware:*:*:*:*:*:*:*:* |
| Vulnerable | CPE |
|---|---|
| No | cpe:2.3:h:schneider-electric:modicon_m580:-:*:*:*:*:*:*:* |
| Vulnerable | CPE |
|---|---|
| Yes | cpe:2.3:o:schneider-electric:modicon_m340_firmware:*:*:*:*:*:*:*:* |
| Vulnerable | CPE |
|---|---|
| No | cpe:2.3:h:schneider-electric:modicon_m340:-:*:*:*:*:*:*:* |
| Vulnerable | CPE |
|---|---|
| Yes | cpe:2.3:o:schneider-electric:modicon_bmxcra_firmware:*:*:*:*:*:*:*:* |
| Vulnerable | CPE |
|---|---|
| No | cpe:2.3:h:schneider-electric:modicon_bmxcra:-:*:*:*:*:*:*:* |
| Vulnerable | CPE |
|---|---|
| Yes | cpe:2.3:o:schneider-electric:modicon_140cra_firmware:*:*:*:*:*:*:*:* |
| Vulnerable | CPE |
|---|---|
| No | cpe:2.3:h:schneider-electric:modicon_140cra:-:*:*:*:*:*:*:* |