Unified Automation .NET based OPC UA Server SDK before 3.2.2 used in several industrial products are affected by a similar vulnerability as documented in CVE-2023-27321 for the OPC Foundation UA...
SINUMERIK systems, that have been provisioned with Create MyConfig (CMC), are affected by a Insertion of Sensitive Information into Log File vulnerability. When using a CMC package on a NCU or on...
A vulnerability has been identified in the integrated S7-1500 CPU of SINUMERIK ONE and SINUMERIK MC products that could allow an attacker to cause a denial of service condition. In order to...
Several industrial devices are affected by two vulnerabilities that could allow an attacker to cause a denial of service condition via PROFINET DCP network packets under certain circumstances. The...
SINUMERIK ONE, SINUMERIK 840D sl and SINUMERIK 828D are affected by a privilege escalation vulnerability that could allow an authenticated local attacker to escalate their privileges in the...
Industrial Edge Management contains an Authorization Bypass vulnerability that could allow an unauthenticated remote attacker to impersonate other devices onboarded to the system. Siemens has...
SINEMA Remote Connect Client before V3.2 SP2 is affected by multiple vulnerabilities. Siemens has released a new version for SINEMA Remote Connect Client and recommends to update to the latest version.
Multiple NULL pointer dereference vulnerabilities in the affected products could allow an attacker with network access to the webserver, to perform a denial of service attack. Siemens has released...
Siemens Tecnomatix Plant Simulation is affected by a stack-based buffer overflow vulnerability that could be triggered when the application reads files in SPP file format. If a user is tricked to...
Multiple vulnerabilities in the affected products could allow an unauthorized attacker with network access to the webserver of an affected products to perform a denial of service attack. Siemens...
Siemens has released new versions for the affected products and recommends to update to the latest versions.
Two null point dereference vulnerabilities affect multiple SIMATIC software products. These could allow an attacker to cause a persistent denial of service condition in the RPC Server of these...
SIMATIC RFID Readers contain multiple vulnerabilities that could allow an attacker to cause Denial-of-Service, exploit hidden functionality and information exposure. Siemens has released new...
The read out protection of the internal flash of affected devices was not properly set at the end of the manufacturing process. An attacker with physical access to the device could read out the...
SINEMA Remote Connect Server before V3.2 SP2 is affected by multiple vulnerabilities. Siemens has released a new version for SINEMA Remote Connect Client and recommends to update to the latest version.
A vulnerability in SIMATIC S7-200 SMART devices could allow an attacker to cause a denial of service condition if a specially crafted TCP packet is sent to the device. Siemens recommends specific...
A XPath Constraint vulnerability in the Mendix Runtime was discovered, that can affect the running applications. The vulnerability could allow a malicious user to deduce contents of inaccessible...
Nozomi Networks has published information on vulnerabilities in Nozomi Guardian/CMC before 24.2.0. This advisory lists the related Siemens Industrial products affected by these vulnerabilities....
A vulnerability has been identified in the OPC Foundation Local Discovery Server (LDS) [0] of several industrial products. The vulnerability could cause a denial of service condition on the...
Several Siemens products (optionally) offer the use of WibuKey Dongles [1] for licensing. According to a recent publication by WIBU Systems (WIBU-94453 at [2]), the Windows device driver for these...
SINEC Security Monitor before V4.9.0 contains multiple vulnerabilities. Siemens has released a new version for Siemens SINEC Security Monitor and recommends to update to the latest version.
HiMed Cockpit devices before V11.6.2 contain a Kiosk Mode Escape vulnerability that could allow an attacker to escape the restricted environment and gain access to the underlying operating system....
Siemens JT2Go is affected by a stack-based buffer overflow vulnerability that could be triggered when the application reads files in PDF format. If a user is tricked to open a malicious file with...
A Denial-of-Service vulnerability has been identified in LOGO! 8 BM. This vulnerability could allow an attacker to crash a device, if a user is tricked into loading a malicious project file onto...
LOGO! V8.3 BM (incl. SIPLUS variants) devices contain a vulnerability that could allow an electromagnetic fault injection. This could allow an attacker to dump and debug the firmware, including...
SENTRON PAC3200 only provide a 4-digit PIN to protect from administrative access via Modbus TCP interface. Attackers with access to the Modbus TCP interface could easily bypass this protection by...
Simcenter Nastran contains multiple memory corruption vulnerabilities that could be triggered when the application reads files in BDF file formats. If a user is tricked to open a malicious file...
LOGO! V8.3 BM (incl. SIPLUS variants) devices contain a plaintext storage of a password vulnerability. This could allow an attacker with phyiscal access to an affected device to extract user-set...
LOGO! 8 BM (incl. SIPLUS variants) contains multiple web-related vulnerabilities. These could allow an attacker to execute code remotely, put the device into a denial of service state or retrieve...
Siemens Teamcenter Visualization and JT2Go are affected by stack buffer overflow and null pointer dereference vulnerabilities that could be triggered while parsing XML file. If a user is tricked...